Home > Not Working > Air Conditioning Fan Not Working

Air Conditioning Fan Not Working

Contents

The furnice sounds normal but I don't know if the blower is working. Condenser fan runs but only intermittently and has trouble starting Check for loose wires or loose components on the fan unit control circuit board. In older systems with belt-powered fans, the belt can get loose or break and cause the fan to stop spinning properly. Is it possible my compressor is not functioning correctly from the incorrect wiring or overheated when fan stopped working?Reply Jim Plummer says: September 23, 2016 at 11:27 amLiam,Most outdoor units have have a peek here

For location purposes: I live in Houston, TX) Cre8tor3 months ago from Ohio Author Faith - Did this start when you replaced the stat? A bent condenser fan causes stress on the blower fan motor shaft and can destroy the motor. The factory cannot always provide diagnosis, but they are very good at explaining how the system is designed to operate. As for the dimming, it's not all that uncommon for lights to dim when the outdoor unit kicks on with a high amp draw. http://www.hannabery.com/faq20.shtml

Ac Inside Fan Not Working

Field inspection worksheets are included at the back of the volume. However, when the a/c unit turns on to just circulate air (air outside is cooler, and a/c is not "on"), it kicks off for a second and then shuts off. Almost certainly something isn't wired right.Hitmanch and Justlie - Your issues are too complex to try and diagnose via the net. For those who had smoking, call a service company.

It was still humming. Scott Dougherty, Doylestown, PA We just purchased a new Trane furnace with A/C. It's very quiet and efficient. Ac Blower Not Working ie reset buttons, etc.

we have a Carrier, model #38BRC036320 thanks for the help. 12-30-07,02:05 PM #4 pflor Member Join Date Dec 2007 State NJ Posts 1,127 82F ain't cool nor cold...so it can't be I will try your fan trick and see if this could be the capacitor. i changed the fan capacitor and it started running for one day, but the other night it fail again..do you think i need to replace the condenser fan?can i use insulation http://www.ufixit.com/news/home-air-conditioner-not-cooling/ The motor may continue to run, even with the run capacitor disconnected, due to the short.

For best long term results make certain the indoor coil is a factory approved match with your outdoor unit.JimReply Boyce Smith says: August 27, 2016 at 12:36 pmThanks so much for Ac Fan Capacitor Does the fan blade spin freely when the motor is off? I turned everything off, checked all the terminals and connections that I could find, then turned everything back on. It's been over three to four repairs since we have been here.

Ac Fan Not Working In Car

I finally was able to pry the back of the duct work to get to the inside coils (there was no direct access-ugh) and cleaned it. http://georgebrazilhvac.com/blog/why-is-my-outdoor-a-c-units-fan-not-spinning Parts Dual Shaft Fan Motor Please enter your model number so we can show you the part that fits your exact model Where is my model number? Ac Inside Fan Not Working I checked the outdoor unit, the fan is working but I don't hear the compressor. Ac Compressor Not Running what happened????Reply Jim Plummer says: September 2, 2016 at 1:32 pmDebbie, Most common malfunction when nothing is running is the 24 volt transformer located on the furnace.

I recommend calling an a/c tech to check the refrigerant if that is what you are suspecting. navigate here Turned everything on and fan works but compressor just hummed. Thanks for reading and commenting! Meg Sharp Walton, Bethlehem, PA Your installers arrived on time, were professional, informative, and finished up on time. Why Is My Ac Outside Unit Not Turning On

They come out with in a moments notice. Loading... If your air conditioning or heat pump system has lost its cooling capacity or won't start see REPAIR GUIDE for AIR CONDITIONERS. Check This Out Todd15 months ago Thanks - I guess that's to be expected with something this old. (Would it run for a minute if it was shorted, though?) Cre8tor15 months ago from Ohio

This was the first search result. Ac Unit Not Turning On Sign In 360report Dengarden»Home Appliances»How to Diagnose and Repair Your Air Conditioner (A/C) Capacitor How to Diagnose and Repair Your Air Conditioner (A/C) CapacitorUpdated on August 8, 2016 What's Wrong With You are the reason I wrote this.

God Bless you.

I decided to go into the house and turn the thermostat back on to run more testing, and low and behold, the unit kicked on and is now cooling the house. Your guys were very professional, did a great job and were a pleasure to have in our home. Use your smart phone to take a picture of the model number tag. Ac Capacitor Cost See below for more detailed information and pictures. 1.

Chris McGrathMacungie, PA We'd like to tell you how pleased we were with the installation of our new heat pump. So you visited the outside unit and noticed that the fan wasn’t spinning. It's cheap. http://da4design.com/not-working/apartment-air-conditioning-not-working.php If the electrical contacts are burned out, the thermostat won’t work properly The fan motor should always be running when the compressor is on.

June June SamphAllentown, PA To Dan N (Supervisor), today about noon Chris & Phil completed installing a new heat pump system for our second floor. I found the same capacitor for my unit at the local hardware store for $40. I would definitley check on that local vocational tech school gig that pflor mentioned, if no luck there you might even check with your local Sheet Metal Union Hall as most Thanks for any help!Reply Jim Plummer says: August 15, 2016 at 3:25 pmBrian,Yes, it can be the capacitor.

Current draw of fan when running is about 4 Amps. I really appreciate your feedback! What do I do from here?Thanks,AndyReply Jim Plummer says: July 25, 2016 at 2:20 pmAndy,The next step is to verify 24 volts being sent from the terminal board on the indoor If all these things are in the right place and you're still not getting results, please, call a technician.

I appreciate the feedback.Jaime - The stick is a diagnostic method, not a repair. Same result. Our page top photo of a compressor/condenser fan unit shows that a stick had fallen into the fan, blocking the blades and preventing the fan from starting. Would you think this could be the contactor at all?

I would verify the new motor is set up to turn in the correct direction. Sign in to report inappropriate content.