mikie2501 685,697 views 8:13 Check this before calling for air conditioner service - Duration: 1:48. Remember, you need a good ground to complete the circuit. It is not possible to repair the blower motor; if it is defective, you must replace it. If the thermostat works fine with the furnace, the issue probably isn’t the thermostat unless one of the wires has disconnected or arced. http://da4design.com/not-working/air-blower-not-working-in-car.php

Again i call the repair guy he says turn it off and he will be by in the morning. Awesome experience! Is there a possibility that the capacitor is failing very slowly? If the belt is broken the blower wont' spin.

Car Ac Blower Not Working

It is not hard to do but be sure to turn off the power before you do it. Will inquire on line about thermostat and a/c model. Clean the condensate drain. 5. The only thing, is that when we moved in two years ago, the unit would cool the area to the point that I would have to wear long sleeves, with the

Pictured on the right is an interior fan resister assembly from a late 70s GM car or light truck.Special Note: I put together a separate blower motor problems page for Chrysler Turned off the thermostat, and the blower came on, and has been running for 20 minutes. Check These Common Furnace ProblemsVideo and step by step furnace problem guide. Air Conditioner Not Turning On How tight should the furnace or air conditioner blower drive belt be?

Where a condensate pump is used, it connects to a 1/2-inch vinyl or rubber tube that exits outdoors or to a drain. For complete instructions, please see Air Conditioner Doesn’t Cool Well. GM called this astro ventilation. http://www.doityourself.com/forum/air-conditioning-cooling-systems/225028-need-help-c-blower-not-working.html Be sure your filters are clean and that nothing is obstructing air flow.

I'm sorry.Jaece - I always recommend going with the right capacitor. Outside Ac Unit Not Turning On Cause 1 Dual Shaft Fan Motor The dual shaft fan motor (or circulation fan motor) might be defective. Is your AC not working? That said, many a techs would argue this and you may have a bad cap but likely, you have a different problem.Whitger - Yes it could still be bad and in

Indoor Blower Motor Troubleshooting

THANK YOU! http://inspectapedia.com/aircond/HVAC_Blower_Fan.php As you mentioned, I am not a fan of using other capacitors than what the unit is rated for. Car Ac Blower Not Working On one side, the fan blade draws in outside air over the condensing coil to dissipate the heat. Furnace Blower Motor Wont Turn On It's used to control the output speed of the blower motor.

Try setting the thermostat fan switch to the "on" position. http://da4design.com/not-working/auto-fan-blower-not-working.php Cre8tor16 months ago from Ohio Author Mandy - sorry for the delay but I would look into the thermostat first. It may not be pretty, but there's my capacitor. | Source 3. In brief: If your AC is not working at all: 1. Ac Not Working In House

To determine if the thermostat is defective, set the air conditioner to cooling and then use a multimeter to test the thermostat for continuity. Dual capacitor (35/5 microfarads) was replaced 6 weeks ago by service tech.With inside house temperature at 85 degrees, I recently had to use a stick to move the fan blades in Nick4 months ago I was reading and seem to have a similar issue but with the motor and capacitor in the attic for the blower. Check This Out Nebojsa Golic My problem is that ac doesn't cool well, and water is not leaking outside.

If the motor bearings are worn out, replace the motor. Window Air Conditioner Won't Turn On More Reading Green link shows where you are in this article series. But as soon as power is turned off, the fan is easy to turn by hand again.I'm so confused.

In searching most often is said the drain is plugged.

If the fan takes off on its own and keeps going, you very likely have a bad start capacitor. View We look forward to having the opportunity to serve you. I'm not sure what to advise on this one.For those with inconsistent starts, check to make sure the capacitor is the correct size. Central Ac Blower Motor ALuminum ground wires are quite often the culprit since they corrode at connection points or anywhere weather or moisture can come in contact.

Then you can re-tighten the tension once the belt is in place. If the blade does not turn freely, this indicates that the motor bearings are worn out. Outdoor fan not running. - Duration: 9:01. this contact form Truly A+ service.

If the furnace makes rattling noises when it runs, be sure the cover panels are screwed on tight. Field inspection worksheets are included at the back of the volume. One screw and it's out. | Source 5. Scott DoughertyDoylestown,PA Excellent, excellent, excellent job by all on your staff.

Please and thank you! [emailprotected] Gary McClenny See my suggestions above about ants in the contactor. If it has, reconnect it. If the AC doesn’t turn off, it’s likely that the contacts on the outdoor run relay have welded together—something that can happen over time because of frequentelectrical arcing at the relay. It does not fix the problem.

Sometimes wires get "welded" together from heat…or something gets in there that cross-connects them. If I turn the thermostat to OFF and back to COOL, it will make a "Click" noise as it's trying to engage it on. I checked the run capacitor (easy to spot, right on the outside of the blower housing) and it passed a continuity test (my voltmeter doesn't have a capacitance test function). Parts Blower Motor Please enter your model number so we can show you the part that fits your exact model Where is my model number?

There are a few reasons this could happen so you may need someone to come out and take a look at it.Thanks ALL OF YOU for reading! Similar to this: https://www.youtube.com/watch?v=gDgqLbq1jQw Anyone know what the cause could be? Make sure nothing is blocking or limiting air flow anywhere in the system—the air filters, registers, and the compressor. See how mechanics diagnose and repair common failures that can turn on the abs light on any vehicle.

To return to our air conditioning and refrigeration home page go to AIR CONDITIONING & HEAT PUMP SYSTEMS. Cre8tor15 months ago from Ohio Author Todd- yes things could run for a few seconds before the short happens. And idea what it could be. Don Vandervort, HomeTips Sounds like the capacitor may need replacement.